Parameter
Parameters of the fault buer and the fault history
Parameter Description Factory setting
r0945[0…63] Fault code -
r0948[0…63] Fault time received in milliseconds - ms
r0949[0…63] Fault value -
p0952 Fault cases counter 0
r2109[0…63] Fault time removed in milliseconds - ms
r2130[0…63] Fault time received in days -
r2131 Actual fault code -
r2133[0…63] Fault value for oat values -
r2136[0…63] Fault time removed in days -
Extended settings for faults
Parameter Description Factory setting
p2100[0…19] Changing the fault reaction, fault number 0
p2101[0…19] Changing the fault reaction, reaction 0
p2118[0…19] Change message type, message number 0
p2119[0…19] Change message type, type 1
p2126[0…19] Changing the acknowledge mode, fault number 0
p2127[0…19] Changing the acknowledge mode 1
You will nd details in function diagram 8075 and in the parameter description of the List
Manual.
Alarms, faults and system messages
9.4Faults, alarm buer and alarm history
SINAMICS G120C Converters
Operating Instructions, 02/2023, FW V4.7 SP14, A5E34263257B AK 371