FigureA-1 Example of a block: Motorized potentiometer (MOP)
Most of the blocks can be adapted to speci󹪝c applications using parameters.
You cannot change the signal interconnection within the block. However, the
interconnection between blocks can be changed by interconnecting the inputs of a block
with the appropriate outputs of another block.
The signal interconnection of the blocks is realized, contrary to electric circuitry, not using
cables, but in the software.
0DLQVHWSRLQW
0RWRUL]HGSRWHQWLRPHWHU
VHWSRLQWDIWHUWKH
UDPSIXQFWLRQJHQHUDWRU
0RWRUL]HG
SRWHQWLRPHWHU
VHWSRLQWORZHU
0RWRUL]HG
SRWHQWLRPHWHU
VHWSRLQWKLJKHU
352),GULYH
UHFHLYH3='
ELWE\ELW
S

U
U
S
U
S
023
FigureA-2 Example: Signal interconnection of two blocks for digital input 0
Binectors and connectors
Connectors and binectors are used to exchange signals between the individual blocks:
Connectors are used to interconnect "analog" signals (e.g. MOP output speed)
Binectors are used to interconnect digital signals (e.g. "Enable MOP up" command)
%,&2EORFN
%LQHFWRULQSXW
%LQHFWRURXWSXW
%LQHFWRUFRQQHFWRURXWSXW
&RQQHFWRURXWSXW
&RQQHFWRULQSXW
S[[[[
U[[[[
U[[[[
U[[[[
U[[[[
S[[[[
%,
&2
%2
&2%2
&,
FigureA-3 Symbols for binector and connector inputs and outputs
Binector/connector outputs (CO/BO) are parameters that combine more than one binector
output in a single word (e.g. r0052 CO/BO: status word 1). Each bit in the word represents
a digital (binary) signal. This summary reduces the number of parameters and simpli󹪝es
parameter assignment.
Binector or connector outputs (CO, BO or CO/BO) can be used more than once.
Appendix
A.2Interconnecting signals in the converter
SINAMICS G120C Converters
462 Operating Instructions, 02/2023, FW V4.7 SP14, A5E34263257B AK

Table of Contents

Other manuals for Siemens SINAMICS G120C DP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120C DP and is the answer not in the manual?

Siemens SINAMICS G120C DP Specifications

General IconGeneral
Protection RatingIP20
Frequency Range0 to 650 Hz
Control ModesV/f, sensorless vector control
Communication InterfacesPROFIBUS DP
Ambient Temperature-10 to +50 °C (without derating), -10 to +60 °C (with derating)
Overload Capacity150 % rated current for 60 s, 200 % rated current for 3 s
Storage Temperature-40 to +70 °C
Relative Humidity5% to 95% (non-condensing)
Voltage Range200 V to 240 V (±10%), 380 V to 480 V (±10%)
Output Voltage0 V to Supply Voltage