5.4.6 Expert.............................................................................................................................. 133
5.4.7 Identifying the motor data and optimizing the closed-loop control.................................... 137
5.5 Quick commissioning with a PC........................................................................................ 138
5.5.1 Creating a project ............................................................................................................ 138
5.5.2 Transfer converters connected via USB into the project ..................................................... 139
5.5.3 Go online and start the commissioning Wizard ................................................................. 140
5.5.4 Overview of quick commissioning .................................................................................... 141
5.5.5 Commissioning wizard..................................................................................................... 142
5.5.6 Standard Drive Control..................................................................................................... 144
5.5.7 Dynamic Drive Control ..................................................................................................... 146
5.5.8 Expert.............................................................................................................................. 148
5.5.9 Identify motor data .......................................................................................................... 151
5.6 Restoring the factory setting ............................................................................................ 153
5.6.1 Resetting the safety functions to the factory setting.......................................................... 154
5.6.2 Restore the factory settings (without safety functions)...................................................... 156
5.7 Series commissioning ...................................................................................................... 157
5.8 Handling the BOP 2 operator panel................................................................................... 158
5.8.1 Menu structure, symbols and keys.................................................................................... 158
5.8.2 Switching the motor on and o󹪜 ........................................................................................ 159
5.8.3 Changing parameter values.............................................................................................. 160
5.8.4 Changing indexed parameters.......................................................................................... 161
5.8.5 Entering the parameter number directly ........................................................................... 162
5.8.6 Entering the parameter value directly............................................................................... 163
5.8.7 Why can a parameter value not be changed? .................................................................... 164
6 Uploading the converter settings ...................................................................................................... 165
6.1 Why does an upload make sense?..................................................................................... 165
6.2 Uploading to the memory card......................................................................................... 165
6.2.1 Recommended memory cards.......................................................................................... 165
6.2.2 Automatic upload ............................................................................................................ 166
6.2.3 Message for a memory card that is not inserted................................................................ 168
6.2.4 Manual upload with Startdrive ......................................................................................... 168
6.2.5 Manual upload with BOP-2............................................................................................... 169
6.2.6 Safely removing a memory card using the BOP-2 .............................................................. 170
6.2.7 Safely remove the memory card with Startdrive................................................................ 171
6.3 Uploading to the BOP-2.................................................................................................... 172
6.4 Upload to a PC using Startdrive ........................................................................................ 173
6.5 More options for the upload............................................................................................. 173
7 Protecting the converter settings ...................................................................................................... 175
7.1 Write protection............................................................................................................... 175
7.2 Know-how protection ...................................................................................................... 176
7.2.1 Extending the exception list for know-how protection ...................................................... 180
7.2.2 Activating and deactivating know-how protection ............................................................ 181
8 Advanced commissioning.................................................................................................................. 183
8.1 Overview of the converter functions................................................................................. 183
Table of contents
SINAMICS G120C Converters
Operating Instructions, 02/2023, FW V4.7 SP14, A5E34263257B AK 7

Table of Contents

Other manuals for Siemens SINAMICS G120C DP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120C DP and is the answer not in the manual?

Siemens SINAMICS G120C DP Specifications

General IconGeneral
Protection RatingIP20
Frequency Range0 to 650 Hz
Control ModesV/f, sensorless vector control
Communication InterfacesPROFIBUS DP
Ambient Temperature-10 to +50 °C (without derating), -10 to +60 °C (with derating)
Overload Capacity150 % rated current for 60 s, 200 % rated current for 3 s
Storage Temperature-40 to +70 °C
Relative Humidity5% to 95% (non-condensing)
Voltage Range200 V to 240 V (±10%), 380 V to 480 V (±10%)
Output Voltage0 V to Supply Voltage