Default setting 3: "Conveyor systems with 4 xed frequencies"
$FNQRZOHGJHIDXOW
212))ZLWKIL[HGVSHHGVHWSRLQW
)L[HGVSHHGVHWSRLQW
)L[HGVSHHGVHWSRLQW
)L[HGVSHHGVHWSRLQW
$FWXDOVSHHGYDOXH
:DUQLQJ
)DXOW
$2
',
',
',
',
',
'2
'2
DO 0: p0730, DO1: p0731 AO 0: p0771[0] DI0: r0722.0, …, DI5: r0722.5
Fixed speed setpoint 1: p1001, … xed speed setpoint 4: p1004, xed speed setpoint active: r1024
Speed setpoint (main setpoint): p1070[0] = 1024
Several of the DI 0, DI 1, DI 4, and DI 5 = high: the converter adds the corresponding xed speed setpoints.
Designation in the BOP-2: coN 4 SP
Default setting 4: "Conveyor system with eldbus"
&RQWUROYLD352),GULYHWHOHJUDP
$FWXDOVSHHGYDOXH
:DUQLQJ
)DXOW
$2
'2
'2
DO 0: p0730, DO1: p0731 AO 0: p0771[0]
Speed setpoint (main setpoint): p1070[0] = 2050[1]
Designation in the BOP-2: coN Fb
Installing
4.10Connecting the interfaces for the converter control
SINAMICS G120C Converters
Operating Instructions, 02/2023, FW V4.7 SP14, A5E34263257B AK 93