S120 Combi Power Modules
4.9 Technical data
120
SINAMICS S120 Combi
Manual, (GH9), 07/2016, 6SL3097-4AV00-0BP5
Rated current (I
n
)
Base-load current (I
H
)
Intermittent duty current for S6 duty I
S6
(40%)
max
A
ACrms
A
ACrms
A
ACrms
ACrms
4.3
6.5
7.7
12
7.7
12
at 540 V DC link voltage
kW
2.4
4.3
4.3
Pulse frequency feedrate 2
0 … 0.7 x DC link voltage
Output for expansion axis
DC link output current (I
n
DC
Max. electronics output current for expansion axis
Electronics current drawn at 24 V DC
without external fan unit
A
1.5
1.5
1.5
(including losses from the electronics, see Power
loss tables (Page 316))
internal
external
The external 6SL3161-0EP00-0AA0 fan module is
taken into account for the specified losses – also
see Power loss calculation for partial load opera-
W
W
W
425
81
344
537
91
446
634
102
532
Without derating
°C
45
45
45
V
DC
820 ± 2 %
See Chapter Overcurrent protection by means of line
fuses and circuit breakers (Page 38)
Resulting rated short-circuit current SCCR at 480 V
AC
3
1)
The specified power ratings apply to the line voltage range from 380 V to 480 V