Additional system components
9.3 DRIVE-CLiQ Hub Module External DME20
236
SINAMICS S120 Combi
Manual, (GH9), 07/2016, 6SL3097-4AV00-0BP5
9.3.7
Specifications for use with UL approval
Pre-assembled cables
Sensor/actuator cable, 5-pin, variable cable,
free cable end at straight socket M12-SPEEDCON,
cable length: 2, 5, 10, 15 m
SAC-5P-...-186/FS SCO
Up to 100 m on request
Phoenix Contact
Cables to be assembled by the user
Cable
Connector
Cable coil, black PUR/PVC, 5-pin
Conductor colors:
brown/white/blue/black/gray
Cable length: 100 m
SAC-5P-100.0-186/0.75
Article number: 1535590
Sensor/actuator connector, socket, straight, 5-pin,
M12, A-coded
Screw connection, metal knurl,
cable gland Pg9
SACC-M12FS-5CON-PG9-M
Article number: 1681486
Phoenix Contact
Power supply
The DME20 must use one of the following 24 V power supplies with voltage limiting:
SITOP 6EP1x.. or 6ES7307..
SINAMICS Control Supply Module 6SL3100-1DE22-0A...
Cable pin assignment
Table 9- 24 Connection to X524 electronics power supply
Pin
Designation
Technical data
1 (brown)
1)
Electronics power supply
The supply voltage of 20.4 V ... 28.8 V refers to the
(terminal) voltage at the DME20. This must be taken
into account when selecting the cable cross-section
and supply cable lengths.
Pins 1 and 2: jumpered internally
Pins 3 and 4: jumpered internally
2 (white)
1)
Electronics power supply
3 (black)
1)
Electronics ground
4 (blue)
1)
Electronics ground
5 (gray)
1)
Not connected internally
1)
The colors refer to the cable specified above