EasyManua.ls Logo

Siemens SINAMICS S120 Combi - Technical Data; DRIVE-Cliq Coupling; Description; Safety Information

Siemens SINAMICS S120 Combi
352 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Accessories
11.2 DRIVE-CLiQ coupling
284
SINAMICS S120 Combi
Manual, (GH9), 07/2016, 6SL3097-4AV00-0BP5
11.1.5
Technical data
Table 11- 1 Technical data of DRIVE-CLiQ cabinet bushings
Unit
6SL3066-2DA00-0AA0
DRIVE-CLiQ
6FX2003-0DT67
M12
Weight
kg
0.165
0.035
Degree of protection
to IEC 60529
IP54 outside the control cabinet
IP20 or IPXXB inside the con-
trol cabinet
IP67
11.2
DRIVE-CLiQ coupling
11.2.1
Description
The DRIVE-CLiQ coupling is used to connect two DRIVE-CLiQ cables in accordance with
degree of protection IP67 acc. to EN 60529.
In addition to the data lines, the power supply contacts of DRIVE-CLiQ are also routed via
the coupling.
Information on the permissible cable length can be found in Section "DRIVE-CLiQ signal
cables (Page 301)".
11.2.2
Safety information
NOTICE
Damage through use of incorrect DRIVE-CLiQ cables
Damage or malfunctions can occur on the devices or system when incorrect or unreleased
DRIVE-CLiQ cables are used.
Only use suitable DRIVE-CLiQ cables that have been released by Siemens for the
respective application.

Table of Contents

Other manuals for Siemens SINAMICS S120 Combi

Related product manuals