Encoder system connection 
10.4 Sensor Module External SME25 
274 
SINAMICS S120 Combi 
Manual, (GH9), 07/2016, 6SL3097-4AV00-0BP5 
Damage due to an incorrectly connected KTY temperature sensor 
If the KTY temperature sensor was not connected with the correct polarity, motor 
overheating may not be detected. 
• Connect the KTY temperature sensor with the correct polarity.
Danger to life due to electric shock in the event of voltage flashovers at the temperature 
sensor 
Voltage flashovers in the signal electronics can occur in motors without safe electrical 
separation of the temperature sensors. 
• Use temperature sensors that comply with the specifications relating to protectiv
e
s
eparation. 
• If safe electrical separation cannot be guaranteed (for linear motors or third-party
motors, for example), use a Sensor Module External (SME120 or SME125) or Terminal 
Module TM120. 
 
Figure 10-20  Dimension drawing of the Sensor Module External SME25, all data in mm and (inches) 
Article number 6SL3055-0AA00-5HA3