EasyManua.ls Logo

Siemens SINAMICS S120 Combi - Sensor Module External SME25; Description; Interface Description; Overview

Siemens SINAMICS S120 Combi
352 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Encoder system connection
10.4 Sensor Module External SME25
SINAMICS S120 Combi
Manual, (GH9), 07/2016, 6SL3097-4AV00-0BP5
271
10.4
Sensor Module External SME25
10.4.1
Description
Direct encoder systems outside the cabinet can be connected to the Sensor Module External
SME25. The SME25 evaluates these encoder systems and converts the calculated values to
DRIVE-CLiQ.
Direct encoder systems with EnDat 2.1 or SSI with SIN/COS (1 Vpp) incremental signals can
be connected, however without reference signal.
Neither motor nor encoder data are saved in the SME25.
10.4.2
Interface description
10.4.2.1
Overview
Figure 10-18 Interface description SME25

Table of Contents

Other manuals for Siemens SINAMICS S120 Combi

Related product manuals