S120 Combi Power Modules
4.9 Technical data
SINAMICS S120 Combi
Manual, (GH9), 07/2016, 6SL3097-4AV00-0BP5
123
V
DC
DC
820 ± 2 %
(IEC 60947 and UL)
See Chapter Overcurrent protection by means of line
fuses and circuit breakers (Page 38)
Resulting rated short-circuit current SCCR at
480 V AC
External air cooling
3
1)
The specified power ratings apply to the line voltage range from 380 V to 480 V
2)
For operation with an 8 kHz pulse frequency, when using duty cycle S6 with a switch-on
duration of 40%, a derating to 60% is required. Derating is required for S6 duty I
S6
(40 %),
not for peak current I
max
, also see diagram "Rated duty cycles, spindle for a pulse frequency
of 8 kHz".
The following rated duty cycles apply to the Power Modules:
● 6SL3111-3VE21-6FA0
● 6SL3111-3VE21-6EA0
● 6SL3111-3VE22-0HA0
● 6SL3111-4VE21-6FA0
● 6SL3111-4VE21-6EA0
● 6SL3111-4VE22-0HA0