EasyManua.ls Logo

Siemens SINAMICS S120 Combi - Characteristic Curves

Siemens SINAMICS S120 Combi
352 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
S120 Combi Power Modules
4.9 Technical data
SINAMICS S120 Combi
Manual, (GH9), 07/2016, 6SL3097-4AV00-0BP5
123
4 axes Power Modules
6SL3111-
4VE21-
0EA0
4VE21-
6FA0
4VE21-6EA0
4VE22-0HA0
Overvoltage tripping
Undervoltage tripping
V
DC
V
DC
820 ± 2 %
380 ± 2 %
Circuit breaker/fuse
(IEC 60947 and UL)
See Chapter Overcurrent protection by means of line
fuses and circuit breakers (Page 38)
Resulting rated short-circuit current SCCR at
480 V AC
kA
65
65
65
65
Cooling method
External air cooling
Cooling air requirement
m
3
/h
160
160
160
160
Weight
kg
19.4
18.9
18.95
19.05
1)
The specified power ratings apply to the line voltage range from 380 V to 480 V
2)
For operation with an 8 kHz pulse frequency, when using duty cycle S6 with a switch-on
duration of 40%, a derating to 60% is required. Derating is required for S6 duty I
S6
(40 %),
not for peak current I
max
, also see diagram "Rated duty cycles, spindle for a pulse frequency
of 8 kHz".
4.9.1
Characteristic curves
The following rated duty cycles apply to the Power Modules:
6SL3111-3VE21-6FA0
6SL3111-3VE21-6EA0
6SL3111-3VE22-0HA0
6SL3111-4VE21-6FA0
6SL3111-4VE21-6EA0
6SL3111-4VE22-0HA0

Table of Contents

Other manuals for Siemens SINAMICS S120 Combi

Related product manuals