DC link components 
7.1 Control Supply Module CSM 
SINAMICS S120 Combi 
Manual, (GH9), 07/2016, 6SL3097-4AV00-0BP5 
173 
 
Table 7- 6  Technical data 
Line voltage 
V
AC 
3 AC 380 … 480 ± 15 % 
Rated input current 
E rated
AC
DC
DC link voltage 
(continuous input voltage) 
V
DC
  430 … 800 
300 … 430 < 1 min 
800 … 853 < 1 min 
Supply current (at 600 V) 
DC
Overvoltage tripping 
V
DC 
> 882 
Rated output voltage V
A rated 
 
A rated
1)
DC
Rated output power P
A rated
 
Overcurrent limitation for short-circuit  A
DC
  approx. 23 
Current carrying capacity of the 24 V busbar 
DC
Residual ripple (clock frequency approx. 50 
mV
pp
  < 100 
Switching peaks (bandwidth 20 MHz) 
Power loss ride-through (at 400 V AC) 
 
 Line 
 DC link 
(see Power loss tables (Page 316)) 
W 
W 
70 
65 
2)
Type designation: 
listed NKJH: 
3RV1021-1DA10 
3RV2011-1DA.. 
3RV2021-1DA.. 
2.2 … 3.2 (set value 3.2) 
listed DIVQ: 
3RV2711-4AD.. 
Class RK1, J, CC, CF 
Rated current: 
A 
AC
6