Cabinet design and EMC
12.9 Note on control cabinet cooling
SINAMICS S120 Combi
Manual, (GH9), 07/2016, 6SL3097-4AV00-0BP5
319
12.9.4.6
Losses in partial-load operation
Losses in the partial-load range for the S120 Combi
The losses of the S120 Combi in partial-load operation can be calculated using the following
formula:
P
V
= a + b + IN1 x P1 + S1 x I1 + S2 x I2 + S3 x I3 + S4 x I4
With:
a: Electronics losses of the S120 Combi
b: Electronics losses of the external fan unit (Article No.: 6SL3161-0EP00-0AA0)
IN1, S1 - S4: Coefficients to calculate the power loss
P1: Infeed power [kW] (LINE X1)
I1: Spindle current [A] (SPINDLE X2)
I2: Current of the 1st feed axis (servo X3)
I3: Current of the 2nd feed axis (servo X4)
I4: Current of the 3rd feed axis (servo X5)
Table 12- 22 Overview of the coefficients to calculate the total power loss P
V
in the partial-load range
Power Module
a
b
IN1
S1
S2
S3
S4
3 axes Power Module
16 kW / 18 A
36
19.2
11.05
7.1
6.5
6.5
16 kW / 24 A
36
19.2
11.2
7.2
7.2
7.2
20 kW / 30 A 36 19.2 11.5 7.3 7.2 7.2
4-axis Power Module
10 kW / 24 A
38.4
19.2
9.1
14.3 / 7.2
1)
7.7
7.7
7.7
16 kW / 18 A
38.4
19.2
11.05
7.1
7.2
6.5
6.5
16 kW / 24 A
38.4
19.2
11.4
7.2
7.2
7.2
7.2
20 kW / 30 A
38.4
19.2
11.7
7.3
7.7
7.2
7.2
1)
For a pulse frequency of 4 kHz / 8 kHz
Table 12- 23 Overview of the coefficients to calculate the power loss P
V
in the control cabinet for external cooling
Power Module
a
b
IN1
S1
S2
S3
S4
3 axes Power Module
16 kW / 18 A
36
0
1.95
0.6
0.4
0.4
16 kW / 24 A
36
0
2.1
0.6
0.4
0.4
20 kW / 30 A
36
0
2.03
0.6
0.4
0.4
4-axis Power Module
10 kW / 24 A
38.4
0
3.3
1.2 / 0.6
1)
0.4
0.4
0.4
16 kW / 18 A
38.4
0
1.95
0.6
0.4
0.4
0.4
16 kW / 24 A
38.4
0
2.3
0.6
0.4
0.4
0.4
20 kW / 30 A
38.4
0
2.23
0.6
0.4
0.4
0.4
1)
For a pulse frequency of 4 kHz / 8 kHz

Table of Contents

Other manuals for Siemens SINAMICS S120 Combi

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS S120 Combi and is the answer not in the manual?

Siemens SINAMICS S120 Combi Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS S120 Combi
CategoryControl Unit
LanguageEnglish

Related product manuals