System overview 
2.2 System data 
32 
SINAMICS S120 Combi 
Manual, (GH9), 07/2016, 6SL3097-4AV00-0BP5 
 
System data 
Technical data  
The following technical data apply for SINAMICS S120 Combi Power Modules. 
Table 2- 1  Electrical data 
Line connection voltage  3 AC 380 V - 10 % … 3 AC 480 V + 10 % 
Above an installation altitude of 2000 m, an isolating trans-
former must be used (see Chapter Derating as a function of 
the installation altitude and ambient temperature (Page 34)). 
Line supply types  TN, TT, and IT line supplies 
Electronics power supply  24 V DC 15/20 % 
1)
, 
Safety extra-low voltage PELV or SELV 
(see Chapter 24 V DC supply (Page 293)) 
Rated short-circuit current SCCR according to UL508C 
Radio interference suppression  Category C2 acc. to EN 61800-3 
for system versions in conformance with the documentation 
1)
If a motor holding brake is used, restricted voltage tolerances (24 V ± 10 %) may have to be taken into account.
Table 2- 2  Environmental conditions 
Degree of protection  IPXXB acc. to EN 60529,  
open type according to UL508 
Protection class, line supply circuits 
I (with protective conductor connection) 
safety extra-low voltage PELV / SELV 
Permissible cooling medium temperature (air) and installa-
tion altitude in operation  
0°C to +45°C up to an installation altitude of 1000 m without 
derating,  
installation altitude >1000 m up to 4000 m, see the derating 
characteristic (Page 130) with respect to the installation alti-
tude or reduction of the ambient temperature by 3.5 K per 
Chemically active substances
 
Long-term storage in the transport packaging 
Class 1C2 according to EN 60721-3-1 
Transport in the transport packaging 
Class 2C2 according to EN 60721-3-2 
Class 3C2 according to EN 60721-3-3 
Biological environmental conditions 
Long-term storage in the transport packaging 
Class 1B1 according to EN 60721-3-1 
Transport in the transport packaging 
Class 2B1 according to EN 60721-3-2 
Class 3B1 according to EN 60721-3-3 
Long-term storage in the transport packaging 
Class 1M2 according to EN 60721-3-1 
Transport in the transport packaging 
Class 2M3 according to EN 60721-3-2