DRIVE-CLiQ cabinet bushing 
11.1.1
 
A DRIVE-CLiQ cabinet bushing is used to connect the DRIVE-CLiQ cables between the 
inside and outside of the control cabinet. It is used in a control cabinet panel. The data lines 
and the voltage supply contacts of the DRIVE-CLiQ are also routed through the bushing. The 
DRIVE-CLiQ cabinet bushing for DRIVE-CLiQ cables is available with DRIVE-CLiQ 
connector and M12 connector/socket.  
DRIVE-CLiQ cabinet bushing for DRIVE-CLiQ connectors 
The cabinet bushing has degree of protection IP54 according to IEC 60529 from the outside 
towards the inside. Inside the control cabinet, a connection is established according to 
degree of protection IP20 or IPXXB acc. to IEC 60529. So that the complete outside of the 
cabinet bushing, including the DRIVE-CLiQ interface, has degree of protection IP54, a 
DRIVE-CLiQ cable must be used, which as a minimum must also have degree of protection 
IP54. 
DRIVE-CLiQ cabinet bushing for M12 connector/socket 
The cabinet bushing has degree of protection IP67 according to IEC 60529 from the outside 
towards the inside. Inside the cabinet a connection according to degree of protection IP67 in 
compliance with IEC 60529 is realized.