Additional system components
9.3 DRIVE-CLiQ Hub Module External DME20
232
SINAMICS S120 Combi
Manual, (GH9), 07/2016, 6SL3097-4AV00-0BP5
9.3.3.2
X500-X505 DRIVE-CLiQ interfaces
Table 9- 20 X500-X505: DRIVE-CLiQ interfaces
Pin
Signal name
Technical data
1
TXP
Transmit data +
2
TXN
Transmit data -
3
RXP
Receive data +
4 Reserved, do not use
5
Reserved, do not use
6
RXN
Receive data -
7
Reserved, do not use
8
Reserved, do not use
A
+ (24 V)
Power supply
B
M (0 V)
Electronics ground
Connector
type
DRIVE-CLiQ socket
The blanking covers for the DRIVE
-CLiQ interfaces are included in the scope of delivery.
Blanking covers (6 units), article number: 6SL3066-4CA01-0AA0
Note
Only MOTION
-CONNECT DRIVE-CLiQ cables may be used to establish connections.
The maximum length of MOTION
-CONNECT 500 is 100 m and for MOTION-CONNECT
800PLUS cables, 75
m.
9.3.3.3
X524 Electronics power supply
Table 9- 21 X524: Electronics power supply
Pin
Designation
Technical data
1
Electronics power supply
The supply voltage of 20.4 V ... 28.8 V
refers to the (terminal) voltage at the
DME20. This must be taken into account
when selecting the cable cross-section
and supply cable lengths.
Pins 1 and 2: jumpered internally
Pins 3 and 4: jumpered internally
2 Electronics power supply
3
Electronics ground
4
Electronics ground
5 Not connected
Type: 5-pin socket
max. connectable cross-section:
4 x 0.75 mm
2