EasyManua.ls Logo

Siemens SINAMICS S120 Combi - Page 233

Siemens SINAMICS S120 Combi
352 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Additional system components
9.3 DRIVE-CLiQ Hub Module External DME20
SINAMICS S120 Combi
Manual, (GH9), 07/2016, 6SL3097-4AV00-0BP5
233
Note
The maximum cable length for the 24 V s
upply of the DME20 is 100 m.
In case no UL-compliant design is required, is the use of the following cables and connectors
from Siemens is recommended:
Pre-assembled cables
Connecting cable for power supply with M12 plug and M12 socket,
A-coded, 4-pin,
Article number: 6XV1801-5D..
Cables to be assembled by the user
Cable
Connector
24 V DC cable,
2-wire, 2 x 0.75 mm
2
,
Article number: 6XV1812-8A
M12 plug connector,
4-pin, A-coded,
Article number: 6GK1907-0DC10-6AA3
Table 9- 22 Cable length P24 supply cable
Connected
loads
1)
m
1
2
3
4
5
Cross-section
0.34 mm²
75 m
45 m
30 m
25 m
20 m
2 x 0.34 mm²
100 m
90 m
65 m
50 m
40 m
0.75 mm²
100 m
100 m
75 m
60 m
50 m
2 x 0.75 mm²
100 m
100 m
100 m
100 m
100 m
T
a
= 55 °C
100 m DRIVE-CLiQ
1)
Connected motors with DRIVE-CLiQ encoder, DRIVE CLiQ mounted encoder SME