EasyManua.ls Logo

Siemens SINAMICS S120 Combi - Technical Data; DRIVE-Cliq Hub Module External DME20; Description

Siemens SINAMICS S120 Combi
352 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Additional system components
9.3 DRIVE-CLiQ Hub Module External DME20
SINAMICS S120 Combi
Manual, (GH9), 07/2016, 6SL3097-4AV00-0BP5
229
9.2.6
Technical data
Table 9- 19 Technical data of the DMC20
6SL3055-0AA00-6AA1
Unit
Value
Electronics power supply
Voltage
Current (without DRIVE-CLiQ node)
Maximum cable length
V
DC
A
DC
m
24 V DC (20.4 ... 28.8)
0.15
30
PE/ground connection
At the housing with M4 screw
Weight
kg
0.36
9.3
DRIVE-CLiQ Hub Module External DME20
9.3.1
Description
The DRIVE-CLiQ Hub Module External DME20, just like the DRIVE-CLiQ Hub Module
DMC20, is only used to connect direct measuring systems for the feed axes and expansion
axes of the S120 Combi.
The component has degree of protection IP67.
Note
The DME20 should also be used if only one feed axis is coupled with a direct measuring
system.
A fixed topology applies when assigning the particular feed axis to a DRIVE-CLiQ interface
(see Section Topology rules for DRIVE-CLiQ (Page 131)) and this must be observed.