S120 Combi Power Modules
4.3 Interface description
86
SINAMICS S120 Combi
Manual, (GH9), 07/2016, 6SL3097-4AV00-0BP5
4.3.7
X200-X205 DRIVE-CLiQ interfaces
Table 4- 12 X200-X205 DRIVE-CLiQ interfaces
PIN
Signal name
Technical data
1
TXP
Transmit data +
2 TXN Transmit data -
3
RXP
Receive data +
4
NC
5
NC
6
RXN
Receive data -
7
NC
8
NC
A
+ (24 V)
Power supply
B
M (0 V)
Electronics ground
Connector
type
DRIVE-CLiQ socket
The blanking covers for t
he DRIVE-CLiQ interfaces are included in the scope of delivery.
Blanking covers (50 x) Article number: 6SL3066-4CA00-0AA0
Note
DRIVE-CLiQ interface X204
For 3 axes Power Modules of the S120 Combi, there is no DRIVE
-CLiQ interface X204.
Inserting and removing the DRIVE-CLiQ blanking covers
Blanking covers should be attached to the DRIVE-CLiQ interfaces that are not required.
To remove the blanking covers, we recommend that the guiding frame is dismantled. To do
this, first remove all of the connections and the drip protection grid. Then remove the Torx
slotted screw (see below).