DC link components
7.2 Braking Module Booksize
178
SINAMICS S120 Combi
Manual, (GH9), 07/2016, 6SL3097-4AV00-0BP5
NOTICE
Material damage due to loose power connections
Insufficient tightening torques or vibrations can result in faulty electrical connections. This
can cause fire damage or malfunctions.
Tighten all the DC link busbar screws with the specified tightening torques (1.8 Nm
tolerance +30 %).
Check the tightening torques of all power connections at regular intervals and tight
en
t
hem when required. This applies in particular after transport.
Note
If braking resistors other than those described in Section
Braking resistors (Page 188)
(6SN1113
-1AA00-0DA0 and 6SL3100-01BE31-0AA) are used then these could be
destroyed.