Cabinet design and EMC
12.7 Connection system
304
SINAMICS S120 Combi
Manual, (GH9), 07/2016, 6SL3097-4AV00-0BP5
Comparison of MOTION-CONNECT power cables
MOTION-CONNECT 500 power cables are mainly suitable for permanent routing. The
MOTION-CONNECT 800PLUS power cables fulfill all high mechanical requirements for the
use in tow chains. They are resistant to cutting oils.
Table 12- 9 Comparison of the MOTION-CONNECT 500 and MOTION-CONNECT 800PLUS power cables
VDE
1)
cURus or UR/CSA
UR-CSA File No.
2)
Yes
UL758-CSA-C22.2-N.210.2-M90
Yes
Yes
UL758-CSA-C22.2-N.210.2-M90
Yes
0
/V in accordance with EN 50395
Supply conductors
600 V / 1000 V
24 V (EN) 1000 V (UL/CSA)
600 V / 1000 V
24 V (EN) 1000 V (UL/CSA)
Supply conductors
4 kV
4 kV
Operating temperature at the surface
Permanently installed
-20 … +80 °C
-20 … +80 °C
Permanently installed
50 N/mm
2
2
50 N/mm
2
2
Permanently installed
5 x D
max
4 x D
max
30 m/min Up to 300 m/min
2
2
CFC/silicone-free CFC/halogen/silicone-free
IEC 60754-1 / DIN VDE 0472-815
EN 60811-2-1
EN 60811-2-1
PVC PUR, HD22.10 S2
The registration number is printed on the cable jacket.
2)
The file number is printed on the cable jacket.