System
7-93
SINUMERIK 802D sl Operation and Programming Nibbling (BP-N), 06/2006 Edition
6FC5 398-3CP10-0BA0
S Selecting the trigger condition: Position the cursor on the “Trigger condition” field and
select the relevant condition using the toggle key.
No trigger, i.e. the measurement starts directly after selecting the “Start” softkey;
Positive edge;
Negative edge;
Exact stop fine reached;
Exact stop coarse reached.
Use the <Marker on >/< Marker off> softkeys to hide / unhide the gridlines.
Use the markers to determine the differences in the horizontal or vertical direction. To do
this, position the marker on the start point and select the <Fix, H mark> or <Fix T mark>
softkey. The difference between the starting point and the current marker position is now
displayed in the status bar. The softkey labels will change to <Free V mark > or <Free T
mark>.
This function opens another menu level offering softkeys for hiding / unhiding the diagrams.
If a softkey is displayed on a black background, the diagrams are displayed for the selected
trace channel.
Use this function to zoom in / zoom out the time basis.
Use this function to increase / reduce the resolution (amplitude).
Use these softkeys to define the step sizes of the markers.
Fig. 7-20
V mark
OFF
T mark
OFF
Fix
V mark
Fix
T mark
Trace
display
Time
scale +
Time
scale –
Vertical
scale +
Vertical
scale –
Marker
steps