Summary

Safety Information

General Safety Summary

Overview of essential safety precautions to prevent injury or damage.

Measurement Category

Triggering Waveforms

Trigger Source, Mode, Level, and Coupling

Covers source, mode, level, coupling, holdoff, noise rejection.

Serial Communication Triggering and Decoding

I2 C, SPI, UART, CAN, and LIN Analysis

Setup and decoding for I2C, SPI, UART, CAN, LIN.

Math Operations and Functions

Waveform Cursors

Waveform Measurements

Measurement Types, Automatic, All, Gate, and Clear

Covers voltage, time, delay, auto, all, gate, clear measurements.

Save and Recall Functionality

Digital Channels (MSO)

System Settings and Management

System Status, Calibration, and Language

Covers status, self-cal, quick-cal, language, sound.

Pass;Fail Test and Mask Management

Covers pass/fail tests and mask saving/recalling.

AWG Option, IO Interfaces, Web Server, Self-Tests

Covers AWG, IO set (USB/LAN/WLAN), web server, self-tests.

Bode Plot II Application

Performing and Setting Up Bode Plots

Steps to perform and configure Bode plots.

Search Functionality

History Functionality

Factory Setup and Troubleshooting

Restoring Factory Defaults

How to reset the oscilloscope to factory settings.

Troubleshooting Common Issues

Solutions for common problems like display, signal, stability, and connectivity.

Summary

Safety Information

General Safety Summary

Overview of essential safety precautions to prevent injury or damage.

Measurement Category

Triggering Waveforms

Trigger Source, Mode, Level, and Coupling

Covers source, mode, level, coupling, holdoff, noise rejection.

Serial Communication Triggering and Decoding

I2 C, SPI, UART, CAN, and LIN Analysis

Setup and decoding for I2C, SPI, UART, CAN, LIN.

Math Operations and Functions

Waveform Cursors

Waveform Measurements

Measurement Types, Automatic, All, Gate, and Clear

Covers voltage, time, delay, auto, all, gate, clear measurements.

Save and Recall Functionality

Digital Channels (MSO)

System Settings and Management

System Status, Calibration, and Language

Covers status, self-cal, quick-cal, language, sound.

Pass;Fail Test and Mask Management

Covers pass/fail tests and mask saving/recalling.

AWG Option, IO Interfaces, Web Server, Self-Tests

Covers AWG, IO set (USB/LAN/WLAN), web server, self-tests.

Bode Plot II Application

Performing and Setting Up Bode Plots

Steps to perform and configure Bode plots.

Search Functionality

History Functionality

Factory Setup and Troubleshooting

Restoring Factory Defaults

How to reset the oscilloscope to factory settings.

Troubleshooting Common Issues

Solutions for common problems like display, signal, stability, and connectivity.

SIGLENT TECHNOLOGIES SDS1104X-E Specifications

General IconGeneral
Bandwidth100 MHz
Channels4
Sample Rate1 GSa/s
Record Length14 Mpts
Max Input Voltage400 V (DC + AC Peak)
Vertical Resolution8 bits
Display Resolution800 x 480
Input CouplingDC, AC, GND
Operating Temperature0 °C to +50 °C
Display7-inch TFT-LCD
Input Voltage Range±400 V
Waveform Capture Rate100, 000 wfs/s (Normal Mode), 400, 000 wfs/s (Sequence Mode)
InterfacesLAN
Input Impedance1 MΩ ± 1%
Trigger TypesEdge, Pulse, Video, Slope, Pattern