EasyManuals Logo

Siko AG06 User Manual

Siko AG06
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #105 background imageLoading...
Page #105 background image
Communication via CAN bus
AG06
Date: 07.02.2018 Art. No. 85674 Mod. status 055/18 Page 105 of 114
9.13.2.45 241B
h
: Power Supply Voltage
Object 241B
h
contains the supply voltages.
Sub-index
00
h
Description
largest sub-index supported
Access
read-only
PDO mapping
no
Data type
Unsigned8
Default
2
EEPROM
no
Sub-index
01
h
Description
Output stage supply voltage (see chapter 8: Parameter description
Parameter no. 52)
Access
read-only
PDO mapping
no
Data type
Unsigned16
Default
no
EEPROM
no
Sub-index
02
h
Description
Control supply voltage (see chapter 8: Parameter description Parameter
no. 51)
Access
read-only
PDO mapping
no
Data type
Unsigned16
Default
no
EEPROM
no
9.13.2.46 241C
h
: Output Stage Temperature
Object 241C
h
contains the output stage temperature.
Sub-index
00
h
Description
Output stage temperature (see chapter 8: Parameter description
Parameter no. 50)
Access
read-only
PDO mapping
no
Data type
Integer16
Default
no
EEPROM
no