Display and Control Keys
AG06
Date: 07.02.2018 Art. No. 85674 Mod. status 055/18 Page 7 of 114
3 Display and Control Keys
3.1 General
The actuator has a two-line display with special characters and three control keys. The keys
serve for actuator parameterization and control. Two LEDs (1, 2) inform about the actuator's
operating state.
Fig. 2: Control elements
3.2 LCD display
With supply voltage applied to the control, the actual value is displayed in the first line and
the set point value with factory settings in the second line.
The value displayed in the 2
nd
line can be adjusted via parameters.
3.3 LED displays
Actuator is within the programmed position window.
Supply voltage of the output stage is applied.
Actuator is within the programmed position window.
Supply voltage of the output stage is missing.
Actuator is outside the programmed position window.
Actuator is outside the programmed position window.
Supply voltage of the output stage is applied.
Actuator is outside the programmed position window.
Supply voltage of the output stage is missing.
Actuator is within the programmed position window.
NMT state: 'PRE-OPERATIONAL'
blinking pulse-
duty factor 1:5
Table 1: LED displays