Functional Description
AG06
Date: 07.02.2018 Art. No. 85674 Mod. status 055/18 Page 18 of 114
Current limiting
Value range: 25 - 110
(see chapter 8: Parameter description Parameter no. 29)
Contouring error limit
Value range: 1 - 30000
(see chapter 8: Parameter description Parameter no. 28)
Table 6: Limiting values menu
4.3.1.5 Visualization
Display orientation
Selection:
: 0°
: 180°
(see chapter 8: Parameter description Parameter no. 45)
LED 2 orange function
Selection:
: Bus operation display
: Off
(see chapter 8: Parameter description Parameter no. 39)
Red LED 1 function
Selection:
: Indication of the operating status
: Off
(see chapter 8: Parameter description Parameter no. 40)
Green LED 1 function
Selection:
: Indication of the operating status
: Off
(see chapter 8: Parameter description Parameter no. 41)
Decimal places
Selection:
: 0
: 0.0
: 0.00
: 0.000
: 0.0000
(see chapter 8: Parameter description Parameter no. 42)