SIM5350 AT Command Set
This command is used to read values from register of IIC device.
SIM PIN References
NO Vendor
Syntax
Test Command Responses
AT+CRIIC=? OK
Write Command Responses
+CRIIC: <data>
OK
AT+CRIIC=
<addr>,<reg>
ERROR
Defined values
<addr>
Device address. Input format must be hex, such as 0xFF.
<reg>
Register address. Input format must be hex, such as 0xFF.
<data>
Data read. Input format must be hex, such as 0x00—0xFF.
Examples
AT+CRIIC=0x1A, 0x0F
+CRIIC: 0x12
OK
9.11 AT+CFGRI Indicate RI when using URC
Description
This command is used to config whether pulling down the RI pin of UART when URC reported. If
<status> is 1, host may be wake up by RI pin.
SIM PIN References
NO Vendor
Syntax
Test Command Responses
AT+CFGRI=? +CFGRI: (range of supported <status>s), (range of supported
<save>s)
SIM5350_ATC_V1.02 6/9/2014