SIM5350 AT Command Set
ERROR
Defined values
<rssi>
0 113 dBm or less
1 111 dBm
2...30 109... 53 dBm
31 51 dBm or greater
99 not known or not detectable
<ber>
(in percent)
0...7 as RXQUAL values in the table in TS 45.008 [20] subclause 8.2.4 not known or not
detectable
Examples
AT+CSQ
+CSQ: 22,0
OK
6.5 AT+CMEE Report mobile equipment error
Description
This command is used to disable or enable the use of result code “+CME ERROR: <err>” or
“+CMS ERROR: <err>” as an indication of an error relating to the functionality of ME; when
enabled, the format of <err> can be set to numeric or verbose string.
SIM PIN References
NO 3GPP TS 27.007
Syntax
Test Command Responses
AT+CMEE=? +CMEE: (list of supported <n>s)
OK
Read Command Responses
AT+CMEE? +CMEE: <n>
OK
Write Command Responses
OK AT+CMEE=<n>
ERROR