SIM5350 AT Command Set
OK
AT+EPBSE=10,1
OK
6 AT Commands for MT Control and Status
6.1 +CME ERROR Mobile Equipment error result code
Description
This result code is similar to the regular ERROR result code. The format of <err> can be either
numeric or verbose string, by setting AT+CMEE command.
SIM PIN References
NO 3GPP TS 27.007
Syntax
+CME ERROR: <err>
Defined values
<err>
values (numeric format followed by verbose format):
9.2.1 General errors
0 phone failure
1 no connection to phone
2 phone adaptor link reserved
3 operation not allowed
4 operation not supported
5 PH SIM PIN required
6 PH-FSIM PIN required
7 PH-FSIM PUK required
10 SIM not inserted
11 SIM PIN required
12 SIM PUK required
13 SIM failure
14 SIM busy
15 SIM wrong
16 incorrect password
17 SIM PIN2 required
18 SIM PUK2 required