SIM5350 AT Command Set
0 – disable
1 – enable
<m>
0 – COLP not provisioned
1 – COLP provisioned
2 unknown (e.g. no network, etc.)
Examples
AT+COLP?
+COLP: 1,0
OK
ATD10086;
+COLP: "10086",129,,,
OK
4.12 AT+CCFC Call forwarding number and conditions
Description
This command allows control of the call forwarding supplementary service. Registration, erasure,
activation, deactivation, and status query are supported.
SIM PIN References
YES 3GPP TS 27.007
Syntax
Test Command Responses
AT+CCFC=? +CCFC: (list of supported <reason>s)
OK
Write Command Responses
When <mode>=2 and command successful:
+CCFC: <status>,<class1>[,<number>,<type>
[,<subaddr>,<satype>[,<time>]]][<CR><LF>
+CCFC: <status>,<class2>[,<number>,<type>
[,<subaddr>,<satype>[,<time>]]][...]]
OK
ERROR
AT+CCFC=<reason>,<mode
>[,<number>[,<type>[,<clas
s>[,<subaddr>[,<satype>[,<ti
me> ]]]]]]
+CME ERROR:<err>
SIM5350_ATC_V1.02 6/9/2014