SIM5350 AT Command Set
3.16 ATS10 Set Disconnect Delay after Indicating the Absence of Data
Carrier
Description
Automatic disconnect delay.
This parameter specifies the amount of time, in tenths of a second that the DCE will remain
connected to the line (off-hook) after the DCE has indicated the absence of received line signal. If
the received line signal is once again detected before the time specified in S10 expires, the DCE
remains connected to the line and the call continues.
SIM PIN References
YES V.25ter
Syntax
Execute Command Responses
OK ATS10=<value>
ERROR
Defined values
<value>
1 to 254 Number of tenths of a second of delay.
Examples
ATS10=1
OK
3.17 ATT Select Tone Dialing
Description
We do not support.
This setting is ignored.
3.18 ATV Set result code format mode
Description
This parameter setting determines the contents of the header and trailer transmitted with result
codes and information responses.