Page #102 background image
Smart Machine Smart Decision
SIM7000 Series_AT Command Manual_V1.03 102 2018-05-08
Parameter Saving
Mode
AUTO_SAVE_REBOOT
Max Response
Time
-
Reference
Note
5.2.26 AT+NCELLLOCK Lock the special NB-IOT cell
AT+NCELLLOCK Lock the special NB-IOT cell
Test Command
AT+NCELLLO
CK=?
Response
+NCELLLOCK: (0,1),(0-65535),(0-503)
OK
Read Command
AT+NCELLLO
CK?
Response
+NCELLLOCK: <mode>[,<earfcn>,<pci>]
OK
Parameters
See Write Command
Write Command
AT+NCELLLO
CK=<mode>[,<e
arfcn>,<pci>]
Response
OK
If failed:
+CME ERROR: <err>
Parameter
<mode> 0 Unlock
1 Lock
<earfcn> A number in the range 0-
65535 representing the EARFCN
to search
<pci> A number in the range 0-503 representing the Physical Cell ID
to search
Parameter Saving
Mode
AUTO_SAVE_REBOOT
Max Response
Time
-
Reference
Note
5.2.27 AT+NBSC Config NB-IOT Scrambling Feature
Test Command
AT+NBSC=?
Response
+NBSC: (list of supported <mode>s)
SIMCOM COMFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7000 Series and is the answer not in the manual?

SimCom SIM7000 Series Specifications

General IconGeneral
BrandSimCom
ModelSIM7000 Series
CategoryControl Unit
LanguageEnglish

Related product manuals