15.2.10 AT+CGNSTST GNSS NMEA Data Out Put To At Port
AT+CGNSTST GNSS NMEA Data Out Put To At Port
Test Command
AT+CGNSTST=
?
Response
+CGNSTST: (0-1), (1-255)
OK
Parameters
See Write Command
Read Command
AT+CGNSTST?
Response
TA returns the current status of configure
+CGNSTST: <TST>
OK
Parameters
See Write Command
Write Command
AT+CGNSTST=
<TST>[,<cont>]
Response
OK
or
ERROR
Parameters
<TST> 0 Turn off GNSS NMEA data out put to AT port
1 Turn on GNSS NMEA data out put to AT port
<cont> 1-255 the number of NMEA data package
Parameter Saving
Mode
NO_SAVE
Max Response
Time
-
Reference
SIMCOM COMFIDENTIAL FILE