15.2.9 AT+CGNSCFG GNSS NMEA Out Configure
AT+CGNSCFG GNSS NMEA Out Configure
Test Command
AT+CGNSCFG=
?
Response
+CGNSCFG: (list of supported <mode>s )
OK
Parameters
See Write Command
Read Command
AT+CGNSCFG?
Response
TA returns the current status of configure
+CGNSCFG: <mode>
OK
Parameters
See Write Command
Write Command
AT+CGNSCFG=
<mode>
Response
OK
or
ERROR
Parameters
<mode> 0 Turn off GNSS NMEA data out put to USB’s NMEA port
when set AT+CGNSPWR=1/0 through UART
1 Turn on GNSS NMEA data out put to USB’s NMEA port
when set AT+CGNSPWR=1/0 through UART
2 Turn on GNSS NMEA data out put to UART3 port when
set AT+CGNSPWR=1/0
Parameter Saving
Mode
NO_SAVE
Max Response
Time
-
Reference Note
This command only supported in UART port.