Test Command
AT+CSIM=?
Response
OK
Write Command
AT+CSIM=<leng
th>,<Command>
Response
+CSIM: <length>,<response>
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
<length> Integer type: length of characters sent to the TE in
<Command> or <response> (i.e. twice the number of octets in the raw
data).
<Command> String type (string should be included in quotation
marks): hex format: GSM 11.11 SIM Command sent from the ME to the
SIM.
<response> String type(string should be included in quotation
marks): hex format: GSM 11.11 response from SIM to <Command>.
Parameter Saving
Mode
NO_SAVE
Max Response
Time
-
Reference
3GPP TS 27.007
[13]
Note
3.2.22 AT+CBC Battery Charge
AT+CBC Battery Charge
Test Command
AT+CBC=?
Response
+CBC: (list of supported <bcs>s),(list of supported <bcl>s),(<voltage>)
OK
Parameters
See Execution Command
Execution
Command
AT+CBC
Response
+CBC: <bcs>,<bcl>,<voltage>
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
SIMCOM COMFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7000 Series and is the answer not in the manual?

SimCom SIM7000 Series Specifications

General IconGeneral
BrandSimCom
ModelSIM7000 Series
CategoryControl Unit
LanguageEnglish

Related product manuals