SIM7000 Series_AT Command Manual_V1.03 199 2018-05-08
AT+MIPLDISCOV
ERRSP=?
+MIPLDISCOVERRSP:
<ref>,<msgid>,<result>,<length>,<valuestring>
OK
Parameters
See Write Command
Write Command
AT+MIPLDISCOV
ERRSP=<ref>,<ms
gid>,<result>,<leng
th>,<valuestring>
Response
OK
Parameters
<ref> Config id
<msgid> Message id
<result> Result
<length> Number of resourceid
<valuestring> Resource id string
Parameter Saving
Mode
NO_SAVE
Max Response Time -
Reference
Note
13.2.13 AT+MIPLPARAMETERRSP Send response on parameter command
AT+MIPLPARAMETERRSP Send response on parameter command
Test Command
AT+MIPLPARAM
ETERRSP=?
Response
+MIPLPARAMETERRSP: <ref>,<msgid>,<result>
OK
Parameters
See Write Command
Write Command
AT+MIPLPARAM
ETERRSP=<ref>,<
msgid>,<result>
Response
OK
Parameters
<ref> Config id
<msgid> Message id
<result> Result
Parameter Saving
Mode
NO_SAVE
Max Response Time -
Reference
Note
SIMCOM COMFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7000 Series and is the answer not in the manual?

SimCom SIM7000 Series Specifications

General IconGeneral
BrandSimCom
ModelSIM7000 Series
CategoryControl Unit
LanguageEnglish

Related product manuals