SIM7000 Series_AT Command Manual_V1.03 230 2018-05-08
Max Response
Time
-
Reference
Note
18.2.2 AT+CASSL Set protocol and SSL context identifier
Test Command
AT+CASSL=?
Response
+CASSL: (range of supported <cid>s),0,(0-1)
+CASSL: (range of supported <cid>s),1,(0-5)
OK
Parameters
See Write Command
Read Command
AT+CASSL?
Response
If <cid> has been set by AT+CACID and <sslFlag> is 0:
+CASSL: <cid>,<sslFlag>,<protocol>
OK
If <cid> has been set by AT+CACID and <sslFlag> is 1:
+CASSL: <cid>,<sslFlag>,<ctxindex>
OK
If no <cid> has been set by AT+CACID:
OK
Parameter
See Write Command
Write Command
1)If <sslFlag> is 0:
AT+CASSL=<cid>
,<sslFlag>,<protoc
ol>
2)If <sslFlag> is 1:
AT+CASSL=<cid>
,<sslFlag>,<ctxind
ex>
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
<cid> TCP/UDP identifier, interger.
<sslFlag> Interger
0 Not support SSL
1 Support SSL
<protocol> Interger
0 TCP
1 UDP
<ctxindex> The identifier of SSL configurations, see AT+CSSLCFG.
Parameter Saving
Mode
NO_SAVE
SIMCOM COMFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7000 Series and is the answer not in the manual?

SimCom SIM7000 Series Specifications

General IconGeneral
BrandSimCom
ModelSIM7000 Series
CategoryControl Unit
LanguageEnglish

Related product manuals