during the transfer if the FTPTYPE is set to A.
11.2.4 AT+FTPPUTOPT Set FTP Put Type
Test Command
AT+FTPPUTOP
T=?
Response
OK
Read Command
AT+FTPPUTOP
T?
Response
+FTPPUTOPT: <value>
OK
Parameters
See Write Command
Write Command
AT+FTPPUTOP
T=<value>
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
<value> "APPE" For appending file
"STOU" For storing unique file
"STOR" For storing file
Parameter Saving
Mode
NO_SAVE
Max Response
Time
-
Reference
Note
11.2.5 AT+FTPCID Set FTP Bearer Profile Identifier
AT+FTPCID Set FTP Bearer Profile Identifier
Test Command
AT+FTPCID=?
Response
OK
Parameters
See Write Command
Read Command
AT+FTPCID?
Response
+FTPCID: <value>
OK