SIM7000 Series_AT Command Manual_V1.03 188 2018-05-08
11.2.28 AT+FTPMDTM Get the Last Modification Timestamp of Specified File on the
Remote Machine
AT+FTPMDTM Get the
Last Modification Timestamp of Specified File on the Remote
Machine
Test Command
AT+FTPMDTM=
?
Response
OK
Parameters
See Execution Command
Execution
Command
AT+FTPMDTM
Response
If success:
OK
+FTPMDTM: 1,0,<timestamp>
If failed:
OK
+FTPMDTM: 1,<error>
If error is related to ME functionality:
+CME ERROR: <err>
Parameter
<error> See "AT+FTPGET"
<timestamp> The last modification timestamp of the specified file.
Mode
NO_SAVE
Ma
Time
-
Reference Note
The file is specified by the "AT+FTPGETNAME"
"AT+FTPGETPATH" commands.