EasyManuals Logo

SimCom SIM7000 Series At Command Manual

SimCom SIM7000 Series
250 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #96 background imageLoading...
Page #96 background image
Smart Machine Smart Decision
SIM7000 Series_AT Command Manual_V1.03 96 2018-05-08
Mode
Max Response
Time
-
Reference Note
Default value of parameter <mode> is different among SIM70
00 series
project.
5.2.20 AT+CPSMS Power Saving Mode Setting
AT+CPSMS Power Saving Mode Setting
Test Command
AT+CPSMS=?
Response
+CPSMS: (list of supported <mode
>s),(list of supported
<Requested_Periodic-RAU
>s),(list of supported
<Requested_GPRS-READY-timer
>s),(list of supported
<Requested_Periodic-TAU
>s),(list of supported
<Requested_Active-Time>s)
OK
Read Command
AT+CPSMS?
Response
+CPSMS: <mode>,[<Requested_Periodic-RAU>],[<Requested_GPRS-
READY-timer>],[<Requested_Periodic-TAU>],[<Requested_Active-Ti
me>]
OK
Parameters
See Write Command
Write Command
AT+CPSMS=[<
mode>[,<Reques
ted_Periodic-RA
U>[,<Requested_
GPRS-READY-ti
mer>[,<Requeste
d_Periodic-TAU
>[,<Requested_A
ctive-Time>]]]]]
Response
OK
If failed:
+CME ERROR: <err>
Parameters
<mode>
0 Disable the use of PSM
1 Enable the use of PSM
<Requested_Periodic-RAU> Not supported
<Requested_GPRS-READY-timer> Not supported
<Requested_Periodic-TAU>
String type; one byte in an 8 bit format. Requested
extended periodic
TAU value (T3412) to be allocated to the UE in E-
UTRAN. The
requested extended periodic TAU value is coded as one byte
(octet 3) of the GPRS Timer 3 information elem
ent coded as bit
format (e.g. "01000111" equals 70 hours).
For the coding and the
value range, see the GPRS Timer 3 IE in 3GPP TS 24.008 [8]
SIMCOM COMFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7000 Series and is the answer not in the manual?

SimCom SIM7000 Series Specifications

General IconGeneral
BrandSimCom
ModelSIM7000 Series
CategoryControl Unit
LanguageEnglish

Related product manuals