Smart Machine Smart Decision
SIM7000 Series_AT Command Manual_V1.03 96 2018-05-08
Time
-
Reference Note
Default value of parameter <mode> is different among SIM70
project.
5.2.20 AT+CPSMS Power Saving Mode Setting
AT+CPSMS Power Saving Mode Setting
Test Command
AT+CPSMS=?
Response
+CPSMS: (list of supported <mode
<Requested_Periodic-RAU
<Requested_GPRS-READY-timer
<Requested_Periodic-TAU
<Requested_Active-Time>s)
OK
Read Command
AT+CPSMS?
Response
+CPSMS: <mode>,[<Requested_Periodic-RAU>],[<Requested_GPRS-
READY-timer>],[<Requested_Periodic-TAU>],[<Requested_Active-Ti
me>]
OK
Parameters
See Write Command
Write Command
AT+CPSMS=[<
mode>[,<Reques
ted_Periodic-RA
U>[,<Requested_
GPRS-READY-ti
mer>[,<Requeste
d_Periodic-TAU
>[,<Requested_A
ctive-Time>]]]]]
Response
OK
If failed:
+CME ERROR: <err>
Parameters
<mode>
0 Disable the use of PSM
1 Enable the use of PSM
<Requested_Periodic-RAU> Not supported
<Requested_GPRS-READY-timer> Not supported
<Requested_Periodic-TAU>
String type; one byte in an 8 bit format. Requested
TAU value (T3412) to be allocated to the UE in E-
requested extended periodic TAU value is coded as one byte
(octet 3) of the GPRS Timer 3 information elem
format (e.g. "01000111" equals 70 hours).
value range, see the GPRS Timer 3 IE in 3GPP TS 24.008 [8]