If <mt>=1:
+CMTI: <mem3>,<index>
If <mt>=2 (PDU mode enabled):
+CMT: [<alpha>],<length><CR><LF><pdu>
If <mt>=2 (text mode enabled):
+CMT:
<oa>,<scts>[,<tooa>,<fo>,<pid>,<dcs>,<sca>,<tosca>,<length>]<CR><
LF><data>
2. Indicates that new cell broadcast message has been received
If <bm>=2 (PDU mode enabled):
+CBM: <length><CR><LF><pdu>
If <bm>=2 (text mode enabled):
+CBM: <sn>,<mid>,<dcs>,<page>,<pages><CR><LF><data>
3. Indicates that new SMS status report has been received
If <ds>=1 (PDU mode enabled):
+CDS: <length><CR><LF><pdu>
If <ds>=1 (text mode enabled):
+CDS: <fo>,<mr>[,<ra>][,<tora>],<scts>,<dt>,<st>
Parameter Saving
Mode
-
Max Response
Time
-
Reference
3GPP TS 27.005
Note
This command is used to select the procedure how receiving of new
messages from the network is indicated to the TE when TE is active,
e.g. DTR signal is ON. If TE is inactive (e.g. DTR signal is OFF). If
set <mt>2,<mt>3 or <ds>1, make sure <mode>1, otherwise
it will return error..
4.2.9 AT+CPMS Preferred SMS Message Storage
Test Command
AT+CPMS=?
Response
+CPMS: (list of supported <mem1>s),(list of supported <mem2>s),(list of
supported <mem3>s)
OK
Parameters
See Write Command
Read Command
AT+CPMS?
Response
+CPMS: <mem1>,<used1>,<total1>,<mem2>,<used2>,<total2>,
SIMCOM COMFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7000 Series and is the answer not in the manual?

SimCom SIM7000 Series Specifications

General IconGeneral
BrandSimCom
ModelSIM7000 Series
CategoryControl Unit
LanguageEnglish

Related product manuals