Write Command.
Parameter Saving
Mode
NO_SAVE
Max Response
Time
75 seconds
Reference
Note
6.2.2 AT+CGDCONT Define PDP Context
AT+CGDCONT Define PDP Context
Test Command
AT+CGDCONT
=?
Response
+CGDCONT: (range of supported
<cid>s),<PDP_type>,,,(list of
supported <d_comp>s),(list of supported <h_comp>s)(list of
<ipv4_ctrl>s),(list of <emergency_flag>s)
OK
Parameters
See Write Command
Read Command
AT+CGDCONT
?
Response
+CGDCONT:
[<cid>,<PDP_type>,<APN>,<PDP_addr>,<d_comp>,<h_comp>,<ipv4_
ctrl>,<emergency_flag>[<CR><LF> +CGDCONT:
<cid>,<PDP_type>,<APN>,<PDP_addr>,<d_comp>,<h_comp>,<ipv4_c
trl>,<emergency_flag>[...]]]
OK
Parameters
See Write Command
Write Command
AT+CGDCONT
=<cid>[,<PDP_ty
pe>[,<APN>[,<P
DP_addr>[,<d_c
omp>[,<h_comp
>][,<ipv4_ctrl>[,
<emergency_flag
>]]]]]]
Response
OK
or
ERROR
Parameters
<cid> (PDP Context Identifier) a numeric parameter which
specifies a particular PDP context definition. The parameter
is local to the TE-MT interface and is used in other PDP
context-related commands. The range of permitted values
(minimum value=1) is returned by the test form of the
command.
1…24
<PDP_type> (Packet Data Protocol type) A string parameter which
specifies the type of packet data protocol.
SIMCOM COMFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7000 Series and is the answer not in the manual?

SimCom SIM7000 Series Specifications

General IconGeneral
BrandSimCom
ModelSIM7000 Series
CategoryControl Unit
LanguageEnglish

Related product manuals