<netact> 0 User-specified GSM access technology
Unsolicited Result Code
If <n>=1 and there is a change in the MT network registration status
+CREG: <stat>
If <n>=2 and there is a change in the MT network registration status or a
change of the network cell:
+CREG: <stat>[,<lac>,<ci>,<netact>]
Parameters
See Write Command
Parameter Saving
Mode
-
Max Response
Time
-
Reference
3GPP TS 27.007
[13]
Note
3.2.15 AT+CRSM Restricted SIM Access
AT+CRSM Restricted SIM Access
Test Command
AT+CRSM=?
Response
OK
Write Command
AT+CRSM=<Co
mmand>[,<fileId
>[,<P1>,<P2>,<P
3>[,<data>]]]
Response
+CRSM: <sw1>,<sw2>[,<response>]
OK
ERROR
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
<Command>
176 READ BINARY
178 READ RECORD
192 GET RESPONSE
214 UPDATE BINARY
220 UPDATE RECORD
242 STATUS
All other values are reserved; refer GSM 11.11.
<fileId> Integer type; this is the identifier for an elementary data file on
SIM. Mandatory for every Command except STATUS
<P1>,<P2>,<P3> Integer type, range 0 – 255
Parameters to be passed on by the ME to the SIM; refer GSM
11.11.
SIMCOM COMFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7000 Series and is the answer not in the manual?

SimCom SIM7000 Series Specifications

General IconGeneral
BrandSimCom
ModelSIM7000 Series
CategoryControl Unit
LanguageEnglish

Related product manuals