8.2.30 AT+CIPSENDHEX Set CIPSEND Data Format to Hex
AT+CIPSENDHEX Set CIPSEND Data Format to HEX
Test Command
AT+CIPSENDH
EX=?
Response
+ CIPSENDHEX: (0,1)
OK
Parameters
See Write Command
Write Command
AT+CIPSENDH
EX=<mode>
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
<mode> 0 The default format of output data in AT+CIPSEND.
1 Set the input data in HEX format when using CIPSEND
command to send data.
Parameter Saving
Mode
NO_SAVE
Max Response
Time
-
Reference Note
8.2.31 AT+CIPHEXS Set Output-data Format with suffix
Test Command
AT+CIPHEXS=?
Response
+CIPHEXS: (list of supported <mode>s)
OK
Parameters
See Write Command
Write Command
AT+CIPHEXS=
<mode>
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
<mode> 0 The default format of output data
1 Set the output data with suffix "0d 0a"
2 Set the output data in HEX format with suffix "0d 0a".
Parameter Saving
Mode
NO_SAVE
SIMCOM COMFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7000 Series and is the answer not in the manual?

SimCom SIM7000 Series Specifications

General IconGeneral
BrandSimCom
ModelSIM7000 Series
CategoryControl Unit
LanguageEnglish

Related product manuals