EasyManuals Logo

SimCom SIM7000 Series At Command Manual

SimCom SIM7000 Series
250 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #98 background imageLoading...
Page #98 background image
Smart Machine Smart Decision
SIM7000 Series_AT Command Manual_V1.03 98 2018-05-08
<AcT-type>
4 CAT-M
5 NB-IoT
<Requested_eDRX_value> Requested eDRX value. 4 bit format.
"0000"-"1111"
Parameter Saving
Mode
AUTO_SAVE
Max Response
Time
-
Reference Note
The Requested_eDRX_value
is the value of cycle length, separately
means
5.12,10.24,20.48,40.96,61.44,81.92,102.40,122.88,143.36,163.84,327.
68,655.36,1310.72,2621.44,5242.88,10485.76.(seconds)
5.2.22 AT+CPSI Inquiring UE system information
AT+CPSI Inquiring UE system information
Test Command
AT+CPSI=?
Response
OK
Read Command
AT+CPSI?
If camping on a gsm cell:
+CPSI: <System Mode>,<Operation Mode>,<MCC>-<MNC>,<LA
C>,<Cell ID>,<Absolute RF Ch Num>,<RxLev>,<Track LO Adjus
t>,<C1-C2>
OK
If camping on a CAT-M or NB-IOT cell:
+CPSI: <System Mode>,<Operation Mode>,<MCC>-<MNC>,<TAC>
,<SCellID>,<PCellID>,<Frequency Band>,<earfcn>,<dlbw>,<ulbw>,<
RSRQ>,<RSRP>,<RSSI>,<RSSNR>
OK
If no service:
+CPSI: NO SERVICE,Online
OK
If failed:
+CME ERROR: <err>
Parameters
<System Mode> System mode.
"NO SERVICE"
"GSM"
"LTE CAT-M1"
SIMCOM COMFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7000 Series and is the answer not in the manual?

SimCom SIM7000 Series Specifications

General IconGeneral
BrandSimCom
ModelSIM7000 Series
CategoryControl Unit
LanguageEnglish

Related product manuals