Page #108 background imageLoading...
Page #108 background image
Smart Machine Smart Decision
SIM7000 Series_AT Command Manual_V1.03 108 2018-05-08
4 Reserved
5 UE tries SNR level 2 band scan only
Parameter Saving
Mode
AUTO_SAVE_REBOOT
Max Response
Time
-
Reference Note
The command controls
the band scan for different SNR levels. This
optimization is applicable only for NB-
IOT and it reduces the band
scan time and power consumption.
5.2.34 AT+CNDS Configure Service Domain Preference For NB-IOT
Test Command
AT+CNDS=?
Response
+CNDS: (list of supported <domain>s)
OK
Parameters
See Write Command
Read Command
AT+CNDS?
Response
+CNDS: <domain>
OK
Parameters
See Write Command
Write Command
AT+CNDS=<do
main>
Response
OK
If failed:
+CME ERROR: <err>
Parameters
<domain>
1 PS(Packet Switched Domain) ONLY
2 CS(Circuit Switched Domain) + PS(Packet Switched Domain)
Parameter Saving
Mode
AUTO_SAVE_REBOOT
Max Response
Time
-
Reference Note
The command of AT+CSDP
is used to config service domain
preference for GSM and CAT-
M.If you want to config service domain
preference for NB-IOT,you can use AT+CNDS.
SIMCOM COMFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7000 Series and is the answer not in the manual?

SimCom SIM7000 Series Specifications

General IconGeneral
BrandSimCom
ModelSIM7000 Series
CategoryControl Unit
LanguageEnglish

Related product manuals