+CME ERROR: <err>
Parameters
<cid> see AT+CACID
<readlen> Requested number of data bytes to be read
<recvlen> Data bytes that has been actually received
Mode
NO_SAVE
Time
-
Reference
Note:
After open a connection or send data successfully, module will read data
actively. If module receives data, it will report "
<cid>,<recvlen>" to remind user to read data.
18.2.7 AT+CACLOSE Close a TCP/UDP connection
AT+CACLOSE Close a TCP/UDP connection
AT+CACLOSE=?
+CACLOSE: (range of supported <cid>s)
OK
Parameters
See Write Command
Write Command
AT+CACLOSE=<
cid>
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
<cid> see AT+CACID
Mode
Time
-
Reference
Note
18.2.8 AT+CSSLCFG Configure SSL parameters of a context identifier