SIM7000 Series_AT Command Manual_V1.03 90 2018-05-08
Reference
Note
5.2.12 AT+SGPIO Control the GPIO
AT+SGPIO Control the GPIO
Test Command
AT+SGPIO=?
Response
+SGPIO: (0-1),(0-4),(0-1),(0-1)
OK
Parameters
See Write Command
Write Command
AT+SGPIO=<ope
ration>,<GPIO>,
<function>,<level
>
Response
OK
or
ERROR
Parameters
<operation>
0 Set the GPIO function including the GPIO output.
1 Read the GPIO level. Please note that only when the gpio is
set as input, user can use parameter 1 to read the GPIO level, otherwise the
module will return "ERROR".
<GPIO> The GPIO you want to be set. (
It has relations with the hardware,
please refer to the hardware manual)
<function> Only when <operation> is set to 0, this option takes effect.
0 Set the GPIO to input.
1 Set the GPIO to output
<level> 0 Set the GPIO low level
1 Set the GPIO high level
Para
meter Saving
Mode
NO_SAVE
Max Response
Time
-
Reference Note
5.2.13 AT+SLEDS Set the Timer Period of Net Light
Test Command
AT+SLEDS=?
Response
+SLEDS: (1-3),(0,40-65535),(0,40-65535)
OK
SIMCOM COMFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7000 Series and is the answer not in the manual?

SimCom SIM7000 Series Specifications

General IconGeneral
BrandSimCom
ModelSIM7000 Series
CategoryControl Unit
LanguageEnglish

Related product manuals