Smart Machine Smart Decision
SIM7000 Series_AT Command Manual_V1.03 30 2018-05-08
Reference
V.25ter
Note
2.2.22 AT&D Set DTR Function Mode
AT&D Set DTR Function Mode
Execution
Command
AT&D[<value>]
Response
This parameter determines how the TA responds when circuit 108/2
is changed from the ON to the OFF condition during data mode.
OK
or
ERROR
Parameters
<value> 0 TA ignores status on DTR.
1 ON->OFF on DTR: Change to Command mode with
remaining the connected call.
2 ON->OFF on DTR: Disconnect call, change to Command
mode. During state DTR = OFF is auto-answer off.
Mode
-
Time
Reference
V.25ter
Note
2.2.23 AT&E Set CONNECT Result Code Format About Speed
AT&E Set CONNECT Result Code Format About Speed
Execution
Command
AT&E[<value>]
This parameter setting determines to report Serial connection rate or
Wireless connection speed. It is valid only ATX above 0.
Response
OK
or
Parameters
<value>
0 Wireless connection speed in integer format.
1 Serial connection rate in integer format. Such as: "115200"
NO_SAVE
Time
-