Smart Machine Smart Decision
SIM7000 Series_AT Command Manual_V1.03 23 2018-05-08
1 Result codes are suppressed and not transmitted
Parameter Saving
Mode
Max Response
Time
-
Reference
V.25ter
Note
2.2.11 ATS0 Set Number of Rings before Automatically Answering the Call
ATS0 Set Number of Rings before Automatically Answering the Call
Read Command
ATS0?
Response
<n>
OK
Parameters
See Write Command
Write Command
ATS0=<n>
Response
This parameter setting determines the number of rings before auto-answer.
OK
ERROR
Parameters
<n> 0 Automatic answering is disable.
1-255
Number of rings the modem will wait for before answering
the phone if a ring is detected.
Param
eter Saving
Mode
-
Max Response
Time
-
Reference
V.25ter
Note
If <n>
is set too high, the calling party may hang up before the call can be
answered automatically.
If using cmux port, ATH and AT+CHUP can hang up the call
(automatically answering) only in the CMUX channel 0.
If using dual-physical serial port, ATH and AT+CHUP can hang up the call
(automatically answering) only in UART1.
2.2.12 ATS3 Set Command Line Termination Character
Read Command
ATS3?
Response
<n>
SIMCOM COMFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7000 Series and is the answer not in the manual?

SimCom SIM7000 Series Specifications

General IconGeneral
BrandSimCom
ModelSIM7000 Series
CategoryControl Unit
LanguageEnglish

Related product manuals