SIM7000 Series_AT Command Manual_V1.03 106 2018-05-08
Parameters
See Write Command
Write Command
AT+CNACT=<m
ode>[,<apn>]
Response
OK
If failed:
+CME ERROR: <err>
Parameters
<mode>
0 Deactive
1 Active
2 Auto Active
<apn>
(Access Point Name) A string parameter (string should be included
in quotation marks) which is a logical name that is used to select the
GGSN or the external packet data network. If the value is null or
omitted, then the subscription value will be requested.The default
value is NULL.
<status>
0 Deactived
1 Actived
Mode
Time
-
Reference Note
"+APP PDP: ACTIVE" will be reported if the app network active
"+APP PDP: DEACTIVE" will be reported if the app network deactived.
Auto Active means the will active automatically if the activation failed.
5.2.32 AT+CEDUMP Set whether the module reset when the module is crashed
AT+CEDUMP Set whether the module reset when the module is crashed
Read Command
AT+CEDUMP?
Response
+CEDUMP: <mode>
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
Write Command
AT+CEDUMP
=<mode>
Response
OK
If error is related to ME functionality: